Laboratory Inspection Violations

 
 
Chemical Storage
Fume Hood
CHP Manual
Hazardous Waste
Compressed Gas Cylinders
Housekeeping
Controlled Access
Labeling
Door Signage
Other
Electrical
Peroxide Former
Eyewash
PPE
Fire Extinguisher
Safety Shower
Flammable Storage
Training
Food
 
 
S - Serious Violations;  O - Other than Serious Violations;  F - Facilities Violations
 
  • Chemical Storage   back to top
    S
    Incompatible Chemicals Stored Together
    • Acids/bases
    • Flammables/oxidizers
    • Organic/inorganic Acids
    • Water Reactives/Water or Water-based Compounds
    • Oxidizers Stored on Incompatible Shelf Material
    Example
    Example
    Containers Not Sealed Properly Example
    Containers Compromised
    • Corroded
    • Cracked
    • Leaking
    Example
    O
    Fume hood utilized for storage while actively being utilized for chemical operations  
    F
       

  • CHP Manual   back to top
    S
    None Request
    O
    Not Completed Example
    Varying degrees of incomplete
    • No SOPs for Select Carcinogens, Reproductive Toxins and Acutely Toxic Chemicals
    • No Chemical Inventory
    • No Lab Specific Training Documentation
    • Incomplete ID Page
    • Information Not Current
    Example
    F
       

  • Compressed Gas Cylinders   back to top
    S
    Unsecured Example
    Not secured properly  
    Exceeding limits for storage per UK policy Fact Sheet
    Toxic gases not in continuously ventilated hood or gas cabinet1. Would include but not be limited to:
    arsine, diborane, germane, phosphine, nitric oxide, methyl bromide, boron trifluoride, chlorine, chlorine trifluoride, dichlorosilane, hydrogen fluoride, nitrogen dioxide, phosgene, sulfur tetrafluoride, ammonia, boron trichloride, boron trifluoride, carbon monoxide, carbonyl sulfide, ethyl chloride, hydrogen bromide, hydrogen chloride, hydrogen sulfide, silane, and disilane
    Example
    Incompatible gases stored together
    • Flammables/oxidizers
     
    Utilizing regulator as isolation device Example
    O
    Valve caps not on cylinders in storage Example
    F
       

  • Controlled Access   back to top
    S
       
    O
    Lab left unlocked and unattended  
    Children in lab Example
    Pets in lab  
    F
       

  • Door Signage   back to top
    S
       
    O
    None Forms
    Incomplete  
    Outdated/incorrect information  
    F
       

  • Electrical   back to top
    S
    Damaged/frayed power cords  
    Use of appliances not UL listed for application
    • Blenders
    • Heat guns/hair dryers
     
    O
    Ext cords utilized for permanent wiring Example
    Use of multiple power strips inline Example
    No strain relief on energized cords Example
    F
       

  • Eyewash   back to top
    S
    Blocked/obstructed eyewash Example
    O
       
    F
    Non-compliant eyewash Example
    No eyewash  

  • Fire Extinguisher   back to top
    S
    No Fire extinguisher E-mail
    Fire ext. discharged and not reported  
    Fire ext. blocked Example
    O
    Fire ext. not in wall mount  
    F
    Fire ext. not inspected annually  
    Fire ext. not charged – “not in the green” Example
    Fire ext. not mounted  

  • Flammable Storage   back to top
    S
    Storage amounts exceed Solvent Storage Policy Policy
    Flammables stored in unapproved refrigerator  
    Unapproved flammable storage cabinet
    • Three latch inoperable
    • Not FM or UL listed
     
    Cabinet not closed Example
    Vent caps removed  
    O
       
    F
       

  • Food   back to top
    S
    Evidence consistent with eating and/or drinking in the lab Example
    Storage of food in lab area Example
    O
       
    F
       

  • Fume Hood  back to top
    S
    Sash above working height during use Example
    Alarm rendered inoperable via tampering  
    Using hood when failing Example
    Baffles obstructed Example
    Incompatible chemical utilized with standard fume hood
    • Perchloric acid
    Policy
    O
    Excessive chemicals/equipment in hood Example
    F
    Hood in alarm mode E-mail
    Alarm not functioning E-mail
    No flow indicator and/or alarm Guide

  • Hazardous Waste   back to top
    S
    No label  
    Label incomplete
    • “Hazardous Waste” not on label
    • No date as to when full
    • No name of contents listed
    Example
    Waste not ticketed for pick-up when container full E-mail
    Open containers of HW Example
    Evidence of improper disposal  
    O
       
    F
       

  • Housekeeping   back to top
    S
    Means of egress, i.e., aisles, doorways blocked  
    O
    Chemical stored in aisle ways – obstructing egress and spill potential  
    Slip/Trip hazards – power and extension cords, liquids on floor Example
    Overabundance of combustibles  
    F
       

  • Labeling   back to top
    S
    Chemical containers not labeled Example
    Illegible container labels Example
    Label incomplete
    • No chemical name
     
    O
    Food stuffs utilized for research not labeled for intended use, i.e., “food not to be used for human consumption”  
    F
       

  • Other   back to top
    S
    Machine not guarded  
    O
    No vacuum trap utilized with vacuum source  
    Utilizing chipped or broken glassware  
    Improper disposal of glassware (deposited in regular trash in lab)  
    Overfilled sharps container Example
    No annual certification of biological safety cabinet Example
    F
       

  • Peroxide Former   back to top
    S
    Not dated for disposal in accordance with guide sheet Policy
    Not disposed of by mfg’er expiration date Example
    O
       
    F
       

  • PPE   back to top
    S
    Not wearing PPE in accordance with CHP PPE Hazard Assessment Request
    Improper storage
    • Contamination of PPE
    • Degradation of PPE
    Example
    Improper PPE selected  
    Improper use of PPE
    • Improper type
    • Wearing gloves outside of lab
     
    O
    Improper attire  
    F
       

  • Safety Shower   back to top
    S
    Blocked/obstructed Example
    Shower activation handle tied back Example
    O
       
    F
    No shower  
    Non-compliant shower
    • No stay open valve
     
    Handle height greater than 69  

  • Training   back to top
    S
       
    O
    All affected employees not received Chemical Hygiene Plan/Laboratory Safety Training Training Page
    All affected employees not received Lab Specific Training Training Forms
    F
       

OHS | EHS